Tunnel uplink

Every proxy already leaves the internet through its own dongle. The tunnel uplink is something else: the link your box itself uses to reach our server (the tunnel that carries all proxy connections, and the box's calls to the panel). By default that is the box's default route — normally Ethernet. If Ethernet, your router or your ISP goes down, the tunnel drops and every proxy of the node goes offline, even though each dongle still has data.

With a backup uplink the box moves the tunnel to one of its dongles instead, and back to Ethernet when it works again. Needs agent 1.7.0 or newer; older agents ignore the setting and keep using the default route ("supported": false). In the panel: Nodes → node → Tunnel uplink. Not available to reseller sub-users (404).

modeWhat happens
system (default)Default route (Ethernet) only — the behaviour before this feature.
autoDefault route first. When the tunnel over it fails, the dongles in dongle_ids, in that order. Back to the default route once it has worked for return_after_s seconds.
dongleOnly the dongles in dongle_ids, in order — for a box without Ethernet.

:::warning What it costs

  • While the box is on a backup dongle, that SIM carries the traffic of all proxies of the node (about the node's total traffic, both directions). Check its data plan.
  • Rotating the uplink dongle (auto-rotate, rotation link, API) changes its IP: the tunnel reconnects within a few seconds and open connections on every proxy of the node drop. warnings.auto_rotate_dongle_ids lists chosen dongles that have auto-rotate on — consider Sticky IP for them.
  • Switching uplink drops open proxy connections once; new ones work within seconds. :::
{"node_id": 12, "mode": "auto", "dongle_ids": [9, 7], "return_after_s": 60, "supported": true,
 "status": {"state": "dongle", "text": "Backup: Jio 1", "active": "dongle", "dongle_id": 9, "iface": "huawei81",
            "since": "2026-10-10T19:02:11Z", "switches": 3,
            "last_error": "default route: dial tcp 152.67.6.160:7443: i/o timeout",
            "reported_at": "2026-10-10T19:05:00+00:00"},
 "dongles": [{"id": 7, "label": "Port 30000", "port": 30000, "auto_rotate": false, "uplink_bytes_in": 0, "uplink_bytes_out": 0},
             {"id": 9, "label": "Jio 1", "port": 30001, "auto_rotate": true, "uplink_bytes_in": 1500000, "uplink_bytes_out": 420000}],
 "warnings": {"auto_rotate_dongle_ids": [9]}}
FieldMeaning
mode, dongle_ids, return_after_syour setting (see below)
supportedthe box's agent understands the setting (1.7.0+)
status.statesystem = Ethernet / default route, dongle = a dongle carries the tunnel, none = nothing works right now, unknown = no report in the last 10 minutes (node offline), too_old = agent older than 1.7.0
status.active, dongle_id, ifacewhat the box reported in its last heartbeat (null when unknown)
status.since, switches, last_errorwhen the current uplink became active (UTC), switches since the agent started, latest reason a link failed
donglesthe node's dongles you can pick; uplink_bytes_* = tunnel + panel bytes sent over that dongle while it was the uplink (on top of its own proxy usage)
warnings.auto_rotate_dongle_idschosen dongles with auto-rotate on

The node object also carries a short "uplink": {"mode", "state", "text"}.

GET /nodes/{id}/uplink

Ability: read

curl
Python
Node.js
PHP
curl 'https://proxykite.com/api/v1/nodes/12/uplink' \
  -H "Authorization: Bearer $HYP_TOKEN" \
  -H 'Accept: application/json'

Response 200: {"data": <uplink object>}

PUT /nodes/{id}/uplink

Ability: manage · Who: owner or team admin. The box picks the change up within one heartbeat (~15 s).

Body fieldType
modesystem | auto | donglerequired
dongle_idsarray of 0–3 proxy ids of this node, in orderoptional — missing = keep; auto and dongle need at least one
return_after_sinteger 30–600optional — missing = keep (default 60); used by auto
curl
Python
Node.js
PHP
curl -X PUT 'https://proxykite.com/api/v1/nodes/12/uplink' \
  -H "Authorization: Bearer $HYP_TOKEN" \
  -H 'Accept: application/json' \
  -H 'Content-Type: application/json' \
  -d '{"mode":"auto","dongle_ids":[9,7],"return_after_s":60}'

Response 200: {"data": <uplink object>}. 422 validation_failed for an unknown mode, more than 3 ids, an id that is not a dongle of this node, return_after_s out of range, or auto/dongle without a dongle.

Alerts